Ethernet over copper stops at 100 metres. That limit is not a suggestion: beyond it, link training degrades, PoE current pushes voltage drop further, and intermittent faults begin. Three solutions exist, and choosing the wrong one is expensive in both money and service calls.

Option one, a PoE extender. A midspan extender takes PoE in on one port and delivers PoE out on another, regenerating the Ethernet signal and passing power along. Two units in series reach 200 metres; three reach 300. The catch is power: each extender consumes 3 to 8 W for its own operation, and it takes that from the budget supplied by the upstream switch. A 30 W port feeding two extenders and a 12 W camera may only deliver 8 to 10 W at the camera. Extenders also halve the effective budget per hop, and most are two-pair devices, so a Type 3 or Type 4 device cannot be fed through them.

Option two, a media converter plus fibre. Copper to the local converter, fibre to the remote end, copper again at the camera, with a separate PoE injector or a small PoE switch at the remote end. This solves distance cleanly, isolates the two sites electrically, and removes surge coupling entirely. It costs more per run and needs power at the far end.

Option three, a fibre uplink switch at the remote location. One fibre pair feeds a small PoE switch that serves all cameras in that area. This is the best architecture whenever more than one or two devices sit beyond the limit, because the cost per camera drops sharply and the remote site gets a proper local switch with its own budget.

A decision rule that works in practice: if a single camera is 120 to 180 metres away and you already have an unused extender, use it, but count the power loss. If two or more devices are beyond 100 metres, run fibre to a small PoE switch. If the distance is over 300 metres, fibre is the only sensible answer.

Distance is not the only variable. Consider these four.

Power. Extenders steal budget; fibre does not. On a project already tight on watts, a fibre run to a small switch is often cheaper than buying a larger upstream switch to feed extenders.

Surge exposure. Copper between buildings is an antenna for induced surges. Fibre breaks that path. For inter-building links, this alone usually justifies the fibre.

Power at the far end. A media converter needs mains power at the camera end, which may not exist. A PoE extender needs none, which is its main advantage. A remote PoE switch also needs mains, but often the far end already has a cabinet or a lighting circuit you can tap.

Manageability. Extenders are usually unmanaged and invisible. A remote switch appears in the topology, reports per-port status and can power-cycle a single camera. On a site with a service contract, that visibility is worth more than the hardware difference.

Two installation details decide whether either approach survives. First, always test the link with the actual load attached, not just a ping: measure the delivered power at the far end with an inline tester. Second, label the far end and document the hops. A three-hop extender chain with no labels is a future outage with a mystery attached.

If you have a site that exceeds 100 metres, send the layout with distances, device types and available power at each point. We will model the options with the actual power budget and quote the configuration that survives the second year, not just the first installation.