Most PoE sizing errors come from comparing the wrong two numbers: the switch total budget against the sum of nominal device wattage. The correct comparison includes conversion losses, headroom and temperature derating.

Here is the formula in one line: required PSE budget = total device wattage divided by conversion efficiency, multiplied by one plus headroom, then compared against the derated budget in the datasheet.

Work through it in four steps.

Step one, sum the worst-case device wattage. Use the datasheet maximum, not typical, and include every device that could draw power at the same moment. For a mixed camera job: eighteen fixed cameras at 8 W plus two PTZ at 35 W gives 144 plus 70, or 214 W.

Step two, divide by efficiency. PoE conversion from AC input to port output is typically 85 percent. 214 W divided by 0.85 is 252 W. If the switch is powered by a 48 V DC supply, efficiency may be higher, around 90 percent, but do not assume it without the datasheet.

Step three, add headroom. Twenty to thirty percent covers inrush current when everything powers on together, higher draw in cold weather, and ageing. 252 W times 1.25 is 315 W.

Step four, compare against the derated budget. If the switch is installed in a 55 degree cabinet, apply the derating curve. A unit rated 370 W at 25 degrees may be 300 W at 55. In that case 315 W does not fit and you need the next size up, or you split the load across two switches.

Three worked examples.

Example A, small office: eight PoE+ access points at 20 W each equals 160 W; divided by 0.85 is 188 W; with 25 percent headroom, 235 W. A 24-port PoE+ switch with a 370 W budget is comfortable, and leaves room for cameras later.

Example B, sixteen-camera CCTV retrofit: sixteen cameras at 10 W equals 160 W; 188 W after efficiency; 235 W with headroom. A 16-port switch with a 240 W budget is right at the limit at 25 degrees, and short in a hot riser. Either choose a 16-port model with 300 W or more, or move to a 24-port chassis with a 400 W budget.

Example C, PoE++ project: four Type 4 devices at 70 W and eight Type 3 at 45 W gives 280 plus 360, or 640 W. Divided by 0.85 is 753 W, and with 25 percent headroom, 941 W. No single 24-port switch covers that comfortably, so the practical answer is two switches, or a modular chassis with dual power supplies.

Two refinements worth knowing.

First, cable loss is already inside the standard. 802.3af guarantees 12.95 W at the device from 15.4 W at the port; the 2.45 W difference is the loss over 100 metres of compliant cable. That is why you size against device wattage rather than port wattage, and why you should not add cable loss a second time.

Second, class-based allocation matters on managed switches. A port that reserves 30 W for a device that only draws 8 W wastes budget. Enable class-based or LLDP power allocation so the switch reserves what the device declares, and keep a documented reserve for the ports you intend to grow into.

A budget spreadsheet beats mental arithmetic. Columns for device, quantity, worst-case watts, and running total; a row for efficiency, a row for headroom, a row for derating at your actual ambient. Fill it once per project type and reuse it.

If you send us the device list, we will fill this in for your project and return the calculation with a recommended configuration, including the alternative of splitting the load across two switches where that is cheaper than one oversized unit.